AEK Industrial

Products & Solutions

DMF-Z D-type Right-angle Electromagnetic Pulse Valve

The DMF-Z D-type is a right-angle electromagnetic pulse valve with a 90° angle between inlet and outlet. The catalog specifies installation between an air header and a dust-collector blow pipe to provide cleaning-air pulses.

Product features

A 90° inlet-to-outlet layout is intended for connection between an air header and a dust-collector blow pipe. The operating medium is dry, clean compressed air. The catalog lists AC220V and DC24V, notes that special voltages are optional, and lists an optional explosion-proof coil.

Operating conditions

ItemValue
Working pressure0.3–0.8 MPa (recommended 0.3–0.6 MPa)
Ambient temperature-5–80°C
Relative humidity<85%
Operating mediumDry clean compressed air
VoltageAC220V / DC24V (special voltage optional)
Diaphragm life≥1,000,000 pulses
Nominal diametersφ20 / φ25 / φ40 / φ50 / φ62 / φ76
Connection threadsG3/4" / G1" / G1-1/2" / G2" / G2-1/2" / G3"

Catalog model matrix

ModelLarge diaphragmKv/CvBlowing area (m²)Inlet/outletWeight (kg)
DMF-Z-20Aφ9016.95 / 19.783.5–6G3/4" / φ270.75
DMF-Z-20φ8017.55 / 20.483.5–6G3/4" / G3/4"0.6
DMF-Z-25φ9626.16 / 30.538–10G1" / G1"0.75
DMF-Z-40Sφ11245.82 / 53.4712–16G1-1/2" / G1-1/2"1.2
DMF-Z-50Sφ16061.24 / 71.4718–28G2" / G2"2.35
DMF-Z-62Sφ188129.26 / 150.8527–38G2-1/2" / G2-1/2"3.2
DMF-Z-76Sφ202159.95 / 186.6637–65G3" / G3"4.05

Applications

Connection between an air header and a dust-collector blow pipe to provide air pulses for dust cleaning.

Download AEK datasheet